SkillsLib.ai

Plumbing System Design Optimizer

Generate IPC/UPC-compliant plumbing designs with load calcs and constructability analysis

3.9(32 reviews)
100+ downloads
Updated Nov 2026
Verified SafeSecurity VerifiedThis skill was analyzed by our AI security scanner for harmful content including data exfiltration, system manipulation, credential theft, and prompt injection. No threats were detected.

What You Can Do

You can rapidly generate schematic and design development plumbing systems that comply with IPC/UPC codes, calculate fixture demand loads and pipe sizing, perform pressure and velocity checks, and identify spatial conflicts before detailed design. Claude analyzes your project parameters—building type, fixture counts, water pressure requirements, drainage grades—and produces complete system layouts with compliance narratives and constructability warnings that reduce coordination delays and rework.

Features

Fixture schedule generation

creates complete supply/drain/vent requirements for all plumbing fixtures with code-required sizing

Demand load calculations

computes water supply demand using Hunter Curve methodology and drainage/vent sizing per code tables

Pressure and velocity analysis

verifies water distribution pressures (20–80 PSI), flow velocities (2–8 ft/s), and drainage slopes (1/8–1/4 inch per foot)

Code compliance verification

cross-checks designs against IPC, UPC, and jurisdiction-specific amendments for potable water, sanitary drainage, and vent systems

System routing and layout

generates conceptual plumbing stack configurations, hot water circulation schemes, and service entrance design with clearance requirements

Constructability conflict detection

identifies access restrictions, spatial clashes, maintenance clearances, and renovation scope challenges early in design

Design narrative documentation

produces permit-ready compliance statements and system descriptions for submission to authorities

Storm water and specialty systems

sizes detention/infiltration systems and analyzes grease traps, backflow devices, and pressure regulation schemes

Example Output

Example 1: Office Building Demand Load Calculation

code
Floor Area: 25,000 SF | Occupancy: 250 people

Fixture Schedule:
- 30 Water Closets (20 GPM) → Total: 600 GPM
- 25 Lavatories (4 GPM) → Total: 100 GPM  
- 5 Kitchen Sinks (10 GPM) → Total: 50 GPM

Demand Load (Hunter): 185 GPM peak
Service Line: 2" (180 GPM capacity) ✓ ADEQUATE
Main Vent Stack: 3" (suitable for 3 stories) ✓ CODE COMPLIANT

Constructability Notes: Vent stack located at building core—no obstruction from structural columns. Drainage routing to roof with 1/4" slope achievable.

Example 2: Residential Retrofit Scope

code
Existing: 1/2" copper main with galvanized branches (60 PSI available)
Proposed Additions: 2 bathrooms, 1 kitchen remodel

Pressure Analysis:
- New demand (3 fixtures simultaneous): 45 GPM
- Available at meter: 60 PSI → Adequate
- Recommend: 3/4" PEX main replacement (future-proofs for demand)
- Vent routing: Tie to existing 2" stack (capacity verified) ✓

Required Permits: Plumbing (main/vent work), Mechanical (hot water tank)

What's Included

  • SKILL.md instruction file with plumbing code framework, fixture load tables, and system requirements:
  • Fixture Schedule Template with supply/drain/vent sizing columns and code references:
  • Load Calculation Checklist for demand load, drainage, and vent sizing workflows:
  • Code Compliance Matrix mapping IPC/UPC sections to common design scenarios:
  • Constructability Conflict Checklist for spatial analysis and maintenance access verification:

Who It's For

  • MEP engineers and plumbing designers — validating conceptual layouts and performing rapid load calculations during schematic phase
  • Architects and project managers — reviewing plumbing feasibility and identifying constructability risks early in design
  • Code compliance consultants — verifying IPC/UPC adherence and generating design narratives for permit submissions
  • Renovation and retrofit specialists — defining scope, analyzing existing system capacity, and planning upgrades
  • Facilities managers and building engineers — assessing system performance and planning maintenance accessibility

Best For

  • Water supply demand calculations and service line sizing for commercial and residential buildings
  • Sanitary drainage, vent stack, and storm water system layout and sizing
  • Code compliance verification and design narrative generation for permit submissions
  • Schematic and design development phase constructability reviews and conflict identification
  • Hot water system design, water heater sizing, and recirculation system planning
  • Renovation scope definition and existing system capacity analysis for retrofit projects

You might also like

Traffic Safety Impact Assessment Analyzer
$45
Safety4.0(35)
Traffic Safety Impact Assessment Analyzer

You can conduct comprehensive safety impact assessments for any transportation design intervention—from intersection redesigns to speed reduction corridors. The skill guides you through hazard identification, risk quantification using established methodologies (conflict studies, crash prediction models), and evidence-based mitigation development. You'll produce defensible safety documentation suitable for audits, litigation, and project approvals.

Voice Dna Creator
$40
Voice Dna Creator

This skill deconstructs your writing samples to identify the specific patterns, personality markers, emotional range, language quirks, and formatting habits that make your voice uniquely yours. You'll receive a detailed voice DNA profile that includes your core communication style, signature phrases, emotional tone, formality level, and what you actively avoid—creating a blueprint that AI systems can use to replicate your authentic voice consistently across projects, platforms, and content types.

Earth Retention System Designer
$35
Earth Retention System Designer

Design earth retention systems by inputting soil properties, site geometry, and regulatory requirements. Claude calculates lateral earth pressures using Coulomb, Rankine, and Mononobe-Okabe methods, verifies factors of safety for internal and external stability, compares competing retention concepts (gravity walls, cantilever, anchored, sheet-pile, soil-nail), and generates cost-benefit analysis and regulatory documentation packages ready for permit submission.

Earth Retention Design Analyzer
$40
Earth Retention Design Analyzer

You can input earth retention system parameters—wall type, soil properties, loading conditions, and geometry—and Claude will perform comprehensive stability analysis including bearing capacity, sliding resistance, and overturning checks. The skill generates professional engineering reports with calculated factors of safety, design narratives, and permit-ready documentation that aligns with ASCE 7, ACI 318, and local building code requirements across gravity walls, cantilever walls, soldier pile systems, sheet pile walls, and MSE walls.

Commercial Code Compliance Analyzer
$45
Commercial3.9(27)
Commercial Code Compliance Analyzer

You can submit architectural design documents, floor plans, and project parameters to receive a comprehensive compliance analysis that cross-references IBC, local amendments, zoning ordinances, and ADA accessibility requirements. Claude identifies specific gaps, cites applicable code sections, explains why each gap matters, and provides concrete remediation strategies—all before formal design review submission when corrections are costly and schedule-impacting.

HVAC Load Calculation & Equipment Sizing Assistant
$30
HVAC3.9(32)
HVAC Load Calculation & Equipment Sizing Assistant

You can accelerate HVAC design workflows by inputting building parameters—envelope characteristics, occupancy data, climate conditions, and existing systems—and receiving calculated heating/cooling loads, equipment sizing recommendations, and zone-by-zone analysis. Claude organizes complex building data into actionable design parameters and specification summaries for client review, permit submission, and professional validation against ASHRAE and ACCA standards.

Fire Protection System Design Analyzer
$35
Fire Protection System Design Analyzer

You can rapidly review fire protection system designs by cross-referencing applicable NFPA codes, calculating system hydraulic demands, validating component selections, and identifying compliance gaps. The skill automates technical verification tasks—from pump sizing and sprinkler head spacing to water supply adequacy and backflow preventer specification—reducing manual review time and design errors during development and plan review phases.

Screenpipe Api
$25
Backend4.4(49)
Screenpipe Api

Query your local Screenpipe instance to retrieve screen recordings, audio transcriptions, UI element accessibility trees, keyboard/mouse input logs, and productivity analytics. You can search by keywords, filter by content type (audio, OCR, accessibility, input), set time ranges, and extract structured data about your applications, meetings, and work sessions without sending data to external servers.

$40.00